| | | | MEMBERS OF THE PUBLIC ARE ADVISED THAT THIS MEETING / HEARING IS A PUBLIC PROCEEDING, AND THE CLERK TO THE BOARD IS MAKING AN AUDIO RECORDING OF THE PROCEEDINGS, AND ALL STATEMENTS MADE DURING THE PROCEEDINGS, WHICH RECORDING WILL BE A PUBLIC RECORD, SUBJECT TO DISCLOSURE UNDER THE PUBLIC RECORDS LAW OF FLORIDA. BE AWARE, HOWEVER, THAT THE AUDIO RECORDING MAY NOT SATISFY THE REQUIREMENT FOR A VERBATIM TRANSCRIPT OF THE PROCEEDINGS, DESCRIBED IN THE NOTICE OF THIS MEETING, IN THE EVENT YOU DESIRE TO APPEAL ANY DECISION ADOPTED IN THIS PROCEEDING. | | |
Not available
|
| | 1. | | ROLL CALL | | |
Not available
|
| | 2. | | PLEDGE OF ALLEGIANCE | | |
Not available
|
| | 3. | | ADOPT THE FOLLOWING MINUTES: | | |
Not available
|
2024-14802
| 1 | 3.1. | Minutes | April 1st, 2024. | | |
Not available
|
| | 4. | | PUBLIC COMMENT | | |
Not available
|
| | 5. | | CONSENT AGENDA: STAFF HAS REVIEWED AND RECOMMENDS APPROVAL | | |
Not available
|
2024-14801
| 1 | 5.1. | Consent | Orange Lake RV Phase 2 - Major Site Plan
Project #2023070086 #30456
Mastroserio Engineering | | |
Not available
|
2024-14803
| 1 | 5.2. | Consent | Pointe Grand Ocala South (Revision To 28702) - Major Site Plan Revision
Project #2002080018 #30895
Kimley-Horn & Associates | | |
Not available
|
| | 6. | | SCHEDULED ITEMS: | | |
Not available
|
2024-14804
| 1 | 6.1. | New Business | Max and Sammy's Used Cars - Waiver Request to Minor Site Plan and Buffers
4830 NE 35TH ST
Project #2014020012 #31272
Parcel #24176-000-00 Permit #2024010605
New Phase Construction
LDC 6.8.6 - Buffers - Approved by DRC on 4/1/24
The below item was denied by DRC on 4/1/24. Applicant requests to be reheard. A revised site plan including driveway apron dimensions has been provided.
LDC 2.20.1.B(1) - Minor Site Plan
CODE states A Minor Site Plan shall be submitted for review and approval prior to the issuance of a Building Permit or prior to the construction of site improvements when proposed improvements are in compliance with all of the following thresholds: (1) Collectively, all existing and proposed impervious ground coverage does not exceed 35 percent of the gross site area or 9,000 square feet, whichever is less.
APPLICANT requests waiver due to a 65-foot by 24-foot (1,560 square feet), 200 square feet of concrete, and an old storage building 40-foot by 20-foot (800 square feet) have been removed (earlier demo permits). The building we are installing | | |
Not available
|
2024-14805
| 1 | 6.2. | New Business | Kaffai/McDowell Residence - Waiver Request to Major Site Plan
9491 SW 190TH Avenue RD Dunnellon
Project #2024030042 #31327
Parcel #34663-000-00 Permit #2024031562 & 2024031406
Fagan Construction
Tabled from 4/1/24
LDC 2.21.1.A(1) - Major Site Plan
CODE states A Major Site Plan shall be submitted for review and approval prior to the issuance of a Building Permit or prior to the construction of site improvements when proposed improvements exceed any of the following thresholds: (1) Collectively, all existing and proposed impervious ground coverage equals or exceeds 35 percent of the gross site area or 9,000 square feet.
APPLICANT requests a waiver to the major site plan for a new SFR. The site will be over the allowed 9,000 square feet per Marion County LDC but well under the 35 percent pervious vs impervious. Please see the attached engineered stormwater plan | | |
Not available
|
2024-14806
| 1 | 6.3. | New Business | 31 JUNIPER PASS - Standalone Waiver Request
Project #2024010080 #31107
Parcel #9025-0636-17 Permit #2023122614
Aldana Contracting
Denied 2/12/24 - This is a request to be reheard
LDC 4.2.11.D - Multiple-Family Dwelling (R-3) classification
CODE states Development Standards: Maximum Density: 4 du/acre for Single-family, 6 du/acre for two-family, 8 du/acre for Multiple-family, 8-16 du/acre High-Urban Density (Vested or underlying land use designation, unless qualifies for the density exceptions provisions in Section 4.3.2.) Minimum Lot Area: 7,500 square feet Single-family, 12,500/7,700 square feet Two-family, 12,500/7,700 square feet 3 or more family. Minimum Lot Width: 85/70* feet Single-family, 100/70* feet Two-family, 100/70* feet 3 or more family. Maximum Building Height: 40 feet. Maximum Floor Ratio: None.
APPLICANT states Marion County LDC requires 100 feet of road frontage to construct a multi-family dwelling on a parcel zoned R3. We are requesting a waiver to be allowed to construct a duplex on PID 9025-0636-17, which is zoned R3 but has only 90 feet of | | |
Not available
|
2024-14807
| 1 | 6.4. | New Business | Self Storage - Ocala - Waiver Request to Major Site Plan in Review
Project #2023050138 #30953 Parcel #29697-020-00
Bohler Engineering FL
LDC 6.4.3.H - Preliminary Plat requirements - Approved on 3/25/24
LDC 6.11.8.B(1) - Parking requirements - Approved on 3/25/24
Denied 3/25/24- This is a request to be reheard
LDC 6.8.6.K(2) - Buffers
CODE states B-Type buffer shall consist of a 20-foot wide landscape strip with a buffer wall. The buffer shall contain at least two shade trees and three accent/ornamental trees for every 100 lineal feet or fractional part thereof. Shrubs and groundcovers, excluding turfgrass, shall comprise at least 50 percent of the required buffer.
APPLICANT requesting a waiver to not provide a screening wall along the Type B buffer along the western property boundary. Our justification is that there is already a 6' wood fence along the length of the property boundary, our proposed building will not have any windows or doors along the western property boundary and a combination of proposed and existing landscaping will be used to screen the si | | |
Not available
|
2024-14808
| 1 | 6.5. | New Business | City of Belleview Utilities Water and Sewer Connection Waiver - Waiver Request to Water and Wastewater Connection
9830 SE 36TH AVE Belleview
Project #2024030076 #31346 Parcel #3682-009-001
Freytes Erick R
LDC 6.14.2.B(1)(A) - Connection Requirements & 6.14.2.B(2)(A)1 - Connection Requirements
CODE states new single family residential in the Urban or Rural area shall connect to a centralized water system with available capacity if a water line is within a connection distance of 400 feet.
CODE states new single family residential in the Urban or Rural area shall connect to a central sewer system if a sewer line from a central sewer system with available capacity is within a connection distance of 400 feet and connection may be made to the existing sewer line using a gravity line or an on-site pumping station.
APPLICANT requests a waiver as permittee has a Mobile Home on site mid 1980s that burned in the early 2000s and is now permitting for a new SFR. The new home will be able to use the existing well and septic that are on site. Estimate cost to run on site wate | | |
Not available
|
2024-14809
| 1 | 6.6. | New Business | 3845 SE HWY 42 - Waiver Request to Major Site Plan
3845 SE HWY 42 Summerfield
Project #2024030077 #31347 Parcel #44755-012-00
David Lewis
LDC 2.21.1.A(1) - Major Site Plan
CODE states a Major Site Plan shall be submitted for review and approval prior to the issuance of a Building Permit or prior to the construction of site improvements when proposed improvements exceed any of the following thresholds: (1) Collectively, all existing and proposed impervious ground coverage equals or exceeds 35 percent of the gross site area or 9,000 square feet.
APPLICANT requests a waiver as the max impervious is 9,000 square feet. Currently there is 12,599 square feet of impervious material on the parcel. | | |
Not available
|
2024-14810
| 1 | 6.7. | New Business | Major Site Plan for Hwy 200 Storage Facility - Waiver Request to Major Site Plan in Review
Project #2023110100 #30898 Parcel #3501-100-013, 3501-100-007, 3501-700-301
Abshier Engineering
LDC 6.13.7.B(1) - Geotechnical Criteria
CODE states B. Minimum requirements. (1) Depth. Soil test borings shall be performed to a minimum depth of 10 feet below the proposed finished grade of the bottom of all retention/detention areas or the permanent pool elevation and once the data has been obtained the hole shall be backfilled and compacted.
APPLICANT requests waiver because the site is in candler soils. The borings were taken in an area the Geotech company thought was the lowest point of the pond area. It is very overgrown and missed the location a few feet. The pond is providing 1.33 feet of freeboard.
LDC 6.13.6.A(3)(c) - Stormwater Quality Criteria
CODE states Dry retention systems that have a depth of six feet or less, measured from top of bank to pond bottom, with side slopes that are no steeper than 4:1 and sodded bottoms.
APPLICANT requests waiver because the pond | | |
Not available
|
2024-14811
| 1 | 6.8. | New Business | Minor Site Plan for Dan Wilson - Waiver Request to Minor Site Plan in Review
Project # 2023110014 #30825 Parcel #12869-000-00
Abshier Engineering
LDC 2.20.1.A - Major Site Plan
CODE states when any of the Minor Site Plan thresholds are exceeded, a Major Site Plan is required.
APPLICANT requests waiver as site barely exceeds threshold. Owner will contain excess runoff on site.
LDC 6.12.2.A - Right-of-way
CODE states right-of-way shall be platted or dedicated, meeting the minimum right-of-way width established in Table 6.12-1, to provide for the necessary access and other needed infrastructure improvements supporting the proposed development. Right-of-way can be provided by easement if approved by DRC.
APPLICANT requests waiver as County requesting r-o-w dedication. If r-o-w is needed in the future is can be purchased.
LDC 6.12.12.D - Sidewalks
CODE states at the discretion of the Development Review Committee, in lieu of construction along external streets, the developer may pay a sidewalk fee to the County in an amount necessary to complete construction. Thi | | |
Not available
|
| | 7. | | CONCEPTUAL REVIEW ITEMS: | | |
Not available
|
| | 8. | | DISCUSSION ITEMS: | | |
Not available
|
| | 9. | | OTHER ITEMS: | | |
Not available
|
| | 10. | | ADJOURN: | | |
Not available
|
|